ELA installation cable - 100 V line
1 x 2 x 0.8 mm solid - FRNC - Dca
ELA108H-D
- solid conductor, Ø 0.80 mm
- twisted pair contruction
- flame retardant and non corrosive (FRNC)
- CPR class Dca - s1, d1, a1 acc. to EN50575
Lieferzeit
2-3 Tage
order code: ELA108H-D.100
no. of pairs: | 1 |
outer Ø: | 6.5 mm |
heat of combustion: | 130 kWh/km |
cable color: | grey |
length: | 100 m |
Stock:
short-notice delivery possible
€227.99
/ roll
incl. German VAT and incl. postage within Germany
this product is available for business customers only
order code: ELA108H-D.200
no. of pairs: | 1 |
outer Ø: | 6.5 mm |
heat of combustion: | 130 kWh/km |
cable color: | grey |
length: | 200 m |
Stock:
short-notice delivery possible
€464.64
/ roll
incl. German VAT and incl. postage within Germany
this product is available for business customers only
order code: ELA108H-D.300
no. of pairs: | 1 |
outer Ø: | 6.5 mm |
heat of combustion: | 130 kWh/km |
cable color: | grey |
length: | 300 m |
Stock:
short-notice delivery possible
€682.76
/ roll
incl. German VAT and incl. postage within Germany
this product is available for business customers only
design
conductor: solid bare copper wire, Ø 0.80 mm |
cond. cross section: 0.50 mm² |
core insulation: LSZH, colou code according to VDE 0815 |
taping: polyester foil |
shielding: AL/PETP foil + solid bare copper drain wire, Ø 0.8 mm |
outer jacket: FRNC, grey |
mechanics
min. bending radius: 5x overall diameter |
working temperature: -30°C / +70°C |
flame retardancy: acc. to IEC 60332-3-24 |
halogen-free: acc. to IEC 60754-2 |
low smoke density: acc. to IEC 61034 |
electric
conductor resistance: 36.6 Ω/km |
mutual capacitance: < 120 nF/km |
insulation resistance: > 100 MΩ x km |
test voltage: |
max. operating voltage: 225 V |
- technical data sheet 43.36 kB
- declaration of performance 320.62 kB
- Tender documentation texts: The article texts and article data provided by us are available in downloadable txt format. Data can be used in tender applications. By downloading these files you acknowledge that KLOTZ AIS assumes no liability for the correct further use of the data and in particular for its correctness, given that you receive the data as unprotected txt documents to enable their rapid and convenient further processing.The files and data are the intellectual property of KLOTZ AIS GmbH and must not be changed or used for any purposes other than for tenders. 1.43 kB