bulk cables

Grid  List 

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  1. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    MY206 professional microphone cable - PVC outer jacket

    • 1 x 2 x 0.22 mm² (AWG 24)
    • ultra-low capacitance 60 pF/m (18 pF/ft)
    • extremely flexible
    • available in six different colours
    • successor product of MY206WS is IR206
    Learn More
  2. polyurethane (PUR) - Thermoplastic elastomere, distinguished by extreme fl exibility at low temperatures (down to -40 degrees). It also offers extremely high mechanical strength and is therefor specially suitable for cable jackets in outdoor use.

    MY206UP professional microphone cable - PUR outer jacket

    • 1 x 2 x 0.22 mm² (AWG 24)
    • low-temperature-flexible down to -40 °C
    • extreme robust due to PUR jacket
    • halogen-free
    Learn More
  3. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    IR206 iceRock - prime microphone cable - white

    • 1 x 2 x 0.22 mm² (AWG 24)
    • ultra-low capacitance 60 pF/m (18 pF/ft)
    • extremely flexible
    • UV-resistant
    Learn More
  4. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    MC2000SW superior microphone cable with extra heavy overall sheath

    • 1 x 2 x 0.22 mm² (AWG 24)
    • ultra-low capacitance 60 pF/m (18 pF/ft)
    • extremely flexible
    • extra heavy overall sheath
    Learn More
  5. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    MC5000 high end microphone cable - double spiral shield - PVC

    • 1 x 2 x 0.50 mm² (AWG 20)
    • inner jacket for stabilising pair twisting
    • very low capacitance 55 pF/m (17 pF/ft)
    • double, counter rotating bare copper spiral shield
    Learn More
  6. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    MY250CY durable pro microphone cable - 2 x 0.50 mm² - PVC

    • 1 x 2 x 0.50 mm² (AWG 20)
    • stabilizing polyethylen (PE) intermediate jacket
    • braid shielded wires
    Learn More
  7. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    MY250CH durable pro microphone cable - 2 x 0.50 mm² - FRNC

    • 1 x 2 x 0.50 mm² (AWG 20)
    • stabilizing polyethylen (PE) intermediate jacket
    • flame retardant and non corrosive (FRNC)
    • braid shielded wires
    • CPR class Eca acc. to EN50575
    Learn More
  8. polyvinyl chloride (PVC) - Thermoplastic material with properties that are widely variable by the use of additives. All-purpose jacket material for applications with no special demands.

    SQ414Y StarQuad - 4 x 0.15 mm² - PVC

    • 0.15 mm² conductor cross section (AWG 26)
    • very dense tinned copper spiral shield
    • quad connection: 2 x 0.30 mm² (AWG 22)
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  9. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    SQ418H StarQuad - 4 x 0.18 mm² - FRNC

    • 100% coverage due to an AL foil shield
    • a drain wire enables a convenient and fast assembly
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.30 mm² (AWG 22)
    • CPR class Eca acc. to EN50575
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  10. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    SQM18H04 StarQuad multicore - 4 x 4 x 0.18 mm² - FRNC

    • 0.18 mm² conductor cross section (AWG 25)
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.36 mm² (AWG 22)
    • CPR class Eca acc. to EN50575, SQM18H12 is class Fca
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More

Grid  List 

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5