bulk cables

Grid  List 

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  1. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    MY250CH durable pro microphone cable - 2 x 0.50 mm² - FRNC

    • 1 x 2 x 0.50 mm² (AWG 20)
    • stabilizing polyethylen (PE) intermediate jacket
    • flame retardant and non corrosive (FRNC)
    • braid shielded wires
    • CPR class Eca acc. to EN50575
    Learn More
  2. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    SQ418H StarQuad - 4 x 0.18 mm² - FRNC

    • 100% coverage due to an AL foil shield
    • a drain wire enables a convenient and fast assembly
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.30 mm² (AWG 22)
    • CPR class Eca acc. to EN50575
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  3. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    SQM18H04 StarQuad multicore - 4 x 4 x 0.18 mm² - FRNC

    • 0.18 mm² conductor cross section (AWG 25)
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.36 mm² (AWG 22)
    • CPR class Eca acc. to EN50575, SQM18H12 is class Fca
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  4. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    SQM18H08 StarQuad multicore - 8 x 4 x 0.18 mm² - FRNC

    • 0.18 mm² conductor cross section (AWG 25)
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.36 mm² (AWG 22)
    • CPR class Eca acc. to EN50575, SQM18H12 is class Fca
    • exemplarily illustrated is the 4-pair SQM18H04
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  5. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    SQ422H StarQuad - 4 x 0,22 mm² - FRNC

    • 100% coverage due to an AL foil shield
    • a drain wire enables a convenient and fast assembly
    • flame retardant and non corrosive (FRNC)
    • quad connection: 2 x 0.44 mm² (AWG 21)
    • CPR class Eca acc. to EN50575
    •  
    • ¹ quad connection: two diagonally opposite conductors are attached to one conductor
    • ² each pair from two diagonally opposite conductors forms one transmission path
    Learn More
  6. flame retardant and non corrosive (FRNC) - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -

    P0122H balanced single pair wiring cable - 1 x 2 x 0.22 mm²

    • stranded conductor 7 x 0,20 mm (AWG 24/7)
    • AL/PET foil shield
    • version in FRNC
    • CPR class Eca acc. to EN50575
    Learn More
  7. Flame Retardant Non Corrosive - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    PX22XH02 installation multicore PolyFIX XLPE - 2 x 2 x 0.22 mm²

    • double shielding (pair + overall AL-foil)
    • XLPE insulation (Cross-linked PE) with high temperature properties
    • for reliable soldering without shrinking
    • flame retardant and non corrosive (FRNC)
    • CPR class Eca acc. to EN50575
    • exemplarily illustrated is the 12-pair PX22XH12
    Learn More
  8. Flame Retardant Non Corrosive - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    PX22XH04 installation multicore PolyFIX XLPE - 4 x 2 x 0.22 mm²

    • double shielding (pair + overall AL-foil)
    • XLPE insulation (Cross-linked PE) with high temperature properties
    • for reliable soldering without shrinking
    • flame retardant and non corrosive (FRNC)
    • CPR class Eca acc. to EN50575
    • exemplarily illustrated is the 12-pair PX22XH12
    Learn More
  9. Flame Retardant Non Corrosive - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    PX22XH08 installation multicore PolyFIX XLPE - 8 x 2 x 0.22 mm²

    • double shielding (pair + overall AL-foil)
    • XLPE insulation (Cross-linked PE) with high temperature properties
    • for reliable soldering without shrinking
    • flame retardant and non corrosive (FRNC)
    • CPR class Eca acc. to EN50575
    • exemplarily illustrated is the 12-pair PX22XH12
    Learn More
  10. Flame Retardant Non Corrosive - Comply with ICE standards. Flame retardant and halogen-free cables with combustion gas that does not form aggressive acids in combination with water. Application: Installations (less flexible than e.g. PVC).
    CPR class Eca acc. to EN50575 -
     -

    PX22XH12 installation multicore PolyFIX XLPE - 12 x 2 x 0.22 mm²

    • double shielding (pair + overall AL-foil)
    • XLPE insulation (Cross-linked PE) with high temperature properties
    • for reliable soldering without shrinking
    • flame retardant and non corrosive (FRNC)
    • CPR class Eca acc. to EN50575
    Learn More